The “Operator Information Area” class seems to provide a solution for this problem.
My general case seems to be working correctly with this implementation:
Friend Sub PutTextWithEnter(ByVal field As FieldDefinition, ByVal value As String)
If IsNothing(field) Then Throw New ArgumentNullException("field")
If IsNothing(value) Then Throw New ArgumentNullException("value")
_Presentation.SendKeys(Mid(value.Trim, 1, field.Length).PadRight(field.Length) & "[enter]", field.Row, field.Column)
WaitForEmulator(_Session.Handle)
End Sub
Private Sub WaitForEmulator(ByVal EmulatorHandle As Integer)
Dim Oia As New AutOIATypeLibrary.AutOIA
Oia.SetConnectionByHandle(EmulatorHandle)
Oia.WaitForInputReady()
Oia.WaitForAppAvailable()
End Sub
I give thanks to a user named “khieyzer” on this message board for pointing our this clean and general-purpose solution.
Edit:
After a few weeks debugging and working through timing and resource release issues, this method now reads like:
Private Sub WaitForEmulator(ByRef NeededReset As Boolean)
Dim Oia As New AutOIA
Oia.SetConnectionByHandle(_Presentation.Handle)
Dim inhibit As InhibitReason = Oia.InputInhibited
If inhibit = InhibitReason.pcOtherInhibit Then
_Presentation.SendKeys("[reset]")
NeededReset = True
WaitForEmulator(NeededReset)
Marshal.ReleaseComObject(Oia)
Exit Sub
End If
If Not Oia.WaitForInputReady(6000) Then
If Oia.InputInhibited = InhibitReason.pcOtherInhibit Then
_Presentation.SendKeys("[reset]")
NeededReset = True
WaitForEmulator(NeededReset)
Marshal.ReleaseComObject(Oia)
Exit Sub
Else
Marshal.ReleaseComObject(Oia)
Throw New InvalidOperationException("The system has stopped responding.")
End If
End If
Oia.WaitForInputReady()
Oia.WaitForAppAvailable()
Marshal.ReleaseComObject(Oia)