Timeout error trying to lock table in h2

Yes, you can change the lock timeout. The default is relatively low: 1 second (1000 ms).

In many cases the problem is that another connection has locked the table, and using multi-version concurrency also solves the problem (append ;MVCC=true to the database URL).

EDIT: MVCC=true param is no longer supported, because since h2 1.4.200 it’s always true for a MVStore engine, which is a default engine.